Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Clin Neuroradiol ; 25(3): 241-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24599323

RESUMO

PURPOSE: The evaluation of carotid-cavernous fistulas (CCFs) and the intracranial vasculature has been predominantly carried out using conventional digital subtraction angiography (DSA). Recent developments in time-resolved magnetic resonance angiography (MRA) provide the opportunity to assess both multiple arterial and venous phases with high temporal and spatial resolution. Here, we investigated the feasibility of this technique to functionally assess CCF prior to intervention. METHODS: Six consecutive patients with clinical symptoms of a CCF were scheduled for clinically indicated MRA and underwent a protocol that comprised conventional imaging sequences and high resolution time-resolved MRA with interleaved stochastic trajectories (TWIST). The location of the fistulous communication, the flow pattern, and venous drainage were determined by time-resolved MRA and compared with DSA which was available in five out of six patients. RESULTS: Typical morphological findings (including enlargement of the superior ophthalmic vein, exophthalmos) were found in all cases in both conventional MRI and time-resolved MRA source data. The temporal resolution of time-resolved MRA enabled a good separation of the early filling of the cavernous sinus during the arterial phase. Direct fistulous communication was assessed in three patients with good correlation to DSA, whereas indirect CCF could not definitely be visualized. The time-resolved MRA provided information about the flow pattern and the venous drainage of the fistula in all patients, which is essential for therapy planning. CONCLUSION: Time-resolved MRA provides important morphological and functional information in patients with CCF. Although DSA remains the gold standard for diagnosis and exact classification of fistulas, time-resolved MRA can provide the relevant hemodynamic information to plan interventional treatment as a one-step procedure with a focused diagnostic workup.


Assuntos
Fístula Carótido-Cavernosa/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fístula Carótido-Cavernosa/cirurgia , Tomada de Decisão Clínica/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processos Estocásticos
2.
Clin Neuroradiol ; 25(1): 33-40, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24343701

RESUMO

PURPOSE: We investigated the agreement of dual-energy computed tomography angiography (DE-CTA) and contrast-enhanced magnetic resonance angiography (CE-MRA)in the quantitative measurement of stenoses of the internal carotid artery in comparison with digital subtraction angiography (DSA). METHODS: A total of 21 patients with stenoses of the external carotid artery were investigated with a DE-CTA and CE-MRA before undergoing carotid angioplasty. The grade of the stenoses was assessed in axial multiplanar reformations (MPR) before and multi-intensity projections (MIP) after plaque subtraction (PS) and compared with results from CE-MRA and DSA according to the North American Symptomatic Carotid Endarterectomy Trial. RESULTS: Average grades of stenoses were 80.7 ± 16.1 % (DSA), 81.4 ± 15.3 % (MRA), 80.0 ± 16.7 % (DE-CTA-MPR), and 85.2 ± 14.7 % (DE-CTA-PS-MIP). Of 21 stenoses, 6 were filiform (stenosis grade, 99 %) in the DSA examination. Five of these cases were identified as pseudo-occlusions in MRA, while four were considered as occlusions in DE-CTA-PS-MIP. Another four cases were identified as pseudo-occlusion in DE-CTA-PS-MIP, which were identified as 90 % stenosis in the DSA examination. CONCLUSIONS: In comparison with the gold standard DSA, DE-CTA-MPR had a slightly better agreement in measuring the degree of stenosis of the internal carotid arteries than CE-MRA. In DE-CTA-PS-MIP images, a systematic overestimation has to be taken into account due to partial extinction of the lumen by the PS algorithm. Nevertheless, DE-CTA should be preferred in imaging patients with carotid artery stenosis in the presence of extensive calcifications.


Assuntos
Calcinose/diagnóstico , Estenose das Carótidas/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Calcinose/complicações , Estenose das Carótidas/complicações , Meios de Contraste , Feminino , Humanos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
3.
Neuroradiology ; 55(4): 423-30, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23223824

RESUMO

INTRODUCTION: High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck. METHODS: CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols. RESULTS: Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 ± 16.5 versus 57.3 ± 14.8; p = 0.50) and venous segments (15.8 ± 6.7 versus 18.9 ± 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35% (218.2 ± 30 versus 141.8 ± 20 mGy × cm). CONCLUSIONS: Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis.


Assuntos
Angiografia/métodos , Aorta Torácica/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Carga Corporal (Radioterapia) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
AJNR Am J Neuroradiol ; 33(2): 218-24, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22033719

RESUMO

BACKGROUND AND PURPOSE: IR has recently demonstrated its capacity to reduce noise and permit dose reduction in abdominal and thoracic CT applications. The purpose of our study was to assess the potential benefit of IR in head CT by comparing objective and subjective image quality with standard FBP at various dose levels. MATERIALS AND METHODS: Ninety consecutive patients were randomly assigned to undergo nonenhanced and contrast-enhanced head CT at a standard dose (320 mAs; CTDI, 60.1) or 15% (275 mAs; CTDI, 51.8) and 30% (225 mAs; CTDI, 42.3) dose reduction. All acquisitions were reconstructed with IR in image space, and FBP and images were assessed in terms of quantitative and qualitative IQ. RESULTS: Compared with FBP, IR resulted in lower image noise (P ≤ .02), higher CNR (P ≤ .03), and improved subjective image quality (P ≤ .002) at all dose levels. While degradation of objective and subjective IQ at 15% dose reduction was fully compensated by IR (CNR, 1.98 ± 0.4 at 320 mAs with FBP versus 2.05 ± 0.4 at 275 mAs with IR; IQ, 1.8 versus 1.7), IQ was considerably poorer at 70% standard dose despite using the iterative approach (CNR, 1.98 ± 0.3 at 320 mAs with FBP versus 1.85 ± 0.4 at 225 mAs with IR, P = .18; IQ, 1.8 versus 2.2, P = .03). Linear regression analysis of CNR against tube current suggests that standard CNR may be obtained until approximately 20.4% dose reduction when IR is used. CONCLUSIONS: Compared with conventional FBP, IR of head CT is associated with significant improvement of objective and subjective IQ and may allow dose reductions in the range of 20% without compromising standard image quality.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Masculino , Pessoa de Meia-Idade
5.
Eur J Radiol ; 80(2): e120-5, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20833492

RESUMO

OBJECTIVES: Calcifications adjacent to the vessel lumen often limit the assessment of stenoses at the carotid bifurcation in 3D multi intensity projection images (3D-MIP) using conventional single energy CT. Aim of the study was to evaluate the diagnostic value of 3D-MIP images after subtraction of bone and calcified plaques (PBS) using dual energy CT for the assessment of carotid bifurcation stenoses. MATERIALS AND METHODS: 36 patients with a total of 46 stenoses at the carotid bifurcation were examined with a dual energy CT system. Grade of the stenoses and plaque morphology were assessed in axial multi planar projections (axMPR) and freely rotatable 3D-MIP images before and after PBS and compared with results from DSA. RESULTS: Grade of the stenosis could be evaluated in all 46 cases in DSA, axMPR and 3D-MIP after PBS. However, in 25 cases grade of the stenosis was not assessable prior to PBS. The average grade of the stenosis increased from DSA (81.4%) to axMPR (83.5%) to 3D-MIP before and after PBS (86.5% and 85.6%). The amount of pseudo-occlusions increased in concordance with the grade of the stenosis (0<9<16). Using 3D-MIP reconstructions, plaque morphology could be evaluated in 32/46 stenoses before PBS and in 44/46 cases after PBS. CONCLUSIONS: PBS facilitated the evaluation of grade of the stenosis in all cases. Nevertheless, after PBS stenoses were overrated in 3D-MIP in comparison to DSA and axMPR. Moreover, plaque morphology, as an independent risk factor for stroke, can be evaluated even in calcified plaques after PBS. Therefore dual energy CTA with plaque subtraction has the potential to identify patients with vulnerable plaques better than conventional CTA.


Assuntos
Angiografia Digital/métodos , Calcinose/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia Cerebral/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
6.
Eur J Radiol ; 79(3): 389-99, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20478675

RESUMO

OBJECTIVE: The objective of this article is to describe MR imaging findings of spinal cord pilocytic astrocytomas at first presentation and following neurosurgery and to discuss briefly some of the most common differential diagnoses. CONCLUSION: MR imaging findings in medullary pilocytic astrocytomas consist generally of focal or diffuse cord-enlarging masses that are irregularly shaped, accompanied by cystic elements and hydromyelia, present different degrees of contrast enhancement, high water diffusivity and a propensity for the thoracic and cervical cord.


Assuntos
Astrocitoma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Neoplasias da Medula Espinal/diagnóstico , Astrocitoma/cirurgia , Meios de Contraste , Diagnóstico Diferencial , Humanos , Neoplasias da Medula Espinal/cirurgia
9.
Clin Neuropathol ; 25(3): 123-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16719408

RESUMO

Bronchogenic cysts are rare findings within the central nervous system and even extremely seldom if they are located supratentorially. We report on a 25-year-old man who presented with a single generalized seizure without any accompanying neurological deficit 6 weeks prior to admission. MRI showed a smoothly limited, non-calcified cyst of a maximum of 55 mm in diameter. Large parts of the membrane were removed through a right anterior craniotomy, and a fenestration into the subarachnoidal space was performed. Histopathological examinations revealed a bronchogenic cyst. Previous reports of neurenteric cysts are reviewed. Therapeutic options, pathogenesis and categorization of this uncommon congenital entity are discussed.


Assuntos
Cisto Broncogênico/patologia , Lobo Frontal , Neoplasias Supratentoriais/patologia , Adulto , Cisto Broncogênico/cirurgia , Humanos , Masculino , Neoplasias Supratentoriais/cirurgia
10.
Schweiz Rundsch Med Prax ; 83(18): 548-9, 1994 May 03.
Artigo em Alemão | MEDLINE | ID: mdl-8197343

RESUMO

Working as a neonatology nurse means not only taking care of the very little and sometimes critically ill patients, but also means being confronted with ethical problems. High-tech medicine, we hope, to help our little patients, but can also irritate and endanger their sensible system. That puts us before the question: If it makes sense to use every medical possibility? These conflicts can bring problems into the team of nurses, doctors and parents. It is our aim that we have the time and space to confront such problems and to find solutions.


Assuntos
Doenças do Recém-Nascido/enfermagem , Doenças do Prematuro/enfermagem , Terapia Intensiva Neonatal , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Pais/psicologia , Apoio Social
11.
J Nurs Adm ; 17(10): 11-5, 1987 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3655917

RESUMO

If computerization of patient care information is to be successful, nurses must be involved in the process from the beginning. This article describes the process used by a committee in choosing a hospital information system and the roles of the nurses who served on the committee.


Assuntos
Sistemas de Informação Hospitalar , Serviço Hospitalar de Enfermagem , Proposta de Concorrência , Humanos , Michigan , Comitê de Profissionais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...